Opto NCDT ILR 1020/1100/1150

Opto NCDT ILR 1020/1100/1150



Order Catalog

Description

The optoNCDT ILR series has very compact dimensions using a completely integrated controller. The laser distance sensors of the optoNCDT 1020/1100/1150 series are designed for direct measurements without additional reflector for distances up to 10 metres.


Spesification

 Model  ILR1020-6  ILR1100-6  ILR1150-10
 Measuring range   black 6%  0.2 ... 2.5m  0.5 … 2m  0.5 … 3m
 Measuring range   grey 10%  0.2 ... 6m  0.5 m … 4m  0.5 … 7m
 Measuring range   white 90%  0.2 ... 6m  0.5 m … 6m  0.5 … 10m
 Linearity  ±40mm  ±10mm  ±8mm
 Resolution  1 ... 5mm  0.1mm  0.1mm
 Repeatability  ±10/±15mm 1)  ±5mm  ±4mm
 Response time  80/13ms 1)  12ms  12ms
 Laser class    measuring laser  IR 905nm, laser class 1   IR 900nm, laser class 1
 Laser class    sighting laser red 650nm, laser class 2
Operation temperature 2) -10° … +50°C; -20° … +50°C in continous operation (humidity 5 - 95%, no condensation)
 Storage temperature  -30° … +75°C  
Limit outputs QA/QB (max. 100 mA)
 Switching points  free adjustable (teach in)    adjustable in 1-mm-steps
Switching hysteresis 30mm min. 20mm (adjustable) min. 10mm (adjustable)
Plausibility output  - QS (max. 50mA)
Service output  - QS (max. 50mA)
Serial interface  -

RS422 (2.9ms at 57.6kBaud)

SSI - compatible (GRAY/BINÄR adjustable) (SSI cycle 80μs)

Bus interface  - Profibus or DeviceNet via respective gateway (accessory)
Analogue output    4 - 20mA
Temperature stability <1.2mm/°C <0.5mm/°C <±5mm absolute
Supply 18 - 30 VDC 
Max. consumption  
Connection 5-pin connector M12 12-pin connector M16
Protection class IP 67
Material (housing) ABS shock resistant
Vibration    EN 60947-5-2 10 - 55 Hz, amplitude 1.5mm, period 5min. at resonant frequency or 55Hz, stress time 30min. per axis
Shock EN 60947-5-2 acceleration 30g, pulse duration 11ms, half sinusoid, 3 shocks/axis
Weight appr. 200g appr. 230g
Accessoires page 14 - 15