Phone / Whatsapp

0857 4065 2657 (Mashudy)

0821 1460 7782 (Faoji)

0823 1173 8960 (Fajar)

Phone Office

+62-21 29563045







TUD310 Ultrasonic Flaw Detector

TUD310 Ultrasonic Flaw Detector


Harga
Rp. 97.021.403

Order

Description

Ultrasonic Flaw Detector TUD310


Feature

Features

  • Four ways to present waveform: positive half-wave, negative half- wave, full wave and radio frequency.
  • Automatic gain adjustment, defect equivalent calculation and peak memory function
  • Two high resolution scanning mode: A and B
  • Display of echo envelope
  • Two individual gates setting and alarming function.
  • 32 detecting channels are available with separate detecting parameters and DAC (Distance Amplitude Correction) curves in every channel.
  • Automatic formation of DAC curves, and 30 points’ data can be recorded infinitely, adjustable offset curves and gain correction functions are available.
  • Three detecting modes(single-probe, dual crystal probe and transmission) with automatic calibration function
  • Connected to PC via USB interface with advanced software for data analysis and management.
  • Data and documents are managed with file allocation table (FAT)system, making the management of inspection data more convenient, reliant and faster
  • Super large memory up to 32M, 1000 echo data can be stored.
  • EL Highlight matrix display (no drift with angle, temperature or sunlight)
  • Brand new digital signal circuit is designed for TUD310
  • Digital signal processor (DSP) is used for signals analyzing, making circuit noise reduced properly and waveform more stable.
  • EPSON ink-jet printers can be connected with TUD
  • Real-time waveform display and review

Spesification

 

 Technical Specifications

Items

Description

Scanning range

2.5 mm ~9999 mm

Scanning resolution

0.1mm (2.5mm ~100mm)
1mm (100 mm ~5000mm)

Gain range

0dB ~110 dB

D-delay

-20µs~+3400µs

P-delay

0µs~99.99µs?resolution 0.01µs

Sound speed

1000 m/s~9999m/s

Bandwidth

0.2MHz~15MHz
?Low0.2~1 Mid.0.5~4 High3~15)

Vertical linearity accuracy

?3%

Horizontal linearity accuracy

?0.2%

Dynamic range

?32dB

Rectification

Positive half wave, negative wave, full wave, and RF

Sensitivity leavings

?60dB

Test mode

Pulse-echo, dual and through transmission

Pulser

Spike excitation pulser

Damping

50ohms, 150ohms and 400ohms

Reject

Linear, 0-80% of full screen, variable in steps of 1%

Unit

Metric/inch

Interface

RS232 / USB

Printer

EPSON ink-jet printers

AC requirements

85-264V AC/1.0A,47-63Hz

Temperature

-10?~40?

Humidity

20%~90%RH

Power supply

Li battery4×3.6V 4000mAh

Charging time

4~5hours

Dimension (mm)

243×173×70

Weight (g)

1470